Inspection

Weld Inspection

Weld inspection examines nominated joints against the project requirements using visual examination and suitable complementary NDT. The result describes examined welds, not every joint in an assembly.

Overview

Weld inspection examines nominated joints against the project requirements using visual examination and suitable complementary NDT. The result describes examined welds, not every joint in an assembly.

NDT Australia provides a single enquiry and co-ordination point for industrial inspection through specialist partners. The proposed provider, personnel competence, method-specific qualifications where required, insurance and any separate approval requirements are checked for the actual scope before appointment; no general accreditation or acceptance guarantee is implied.

Assets & Materials

Structural fabrications, pressure components, pipe spools and repair welds need traceable weld identifiers, material details and the relevant design or fabrication specification.

Methods & Limitations

VT documents accessible profile; UT may investigate internal reflectors, MPI suits ferromagnetic surfaces and PT suits clean non-porous surfaces. Method selection and sampling extent are agreed for each weld category.

Geometry, backing, coatings and access can restrict examination. Indications are evaluated against nominated criteria, not a universal pass/fail rule. Procedure qualification, welder qualification and radiography are not automatically included.

Typical Defects & Conditions

  • Crack-like indications at welds and heat-affected areas
  • Internal reflectors where UT is suitable
  • Visible undercut, profile departures and surface porosity

Planning the Inspection

Agree hold points before coating, assembly or loading conceals examination faces. Supply weld preparation details, specified examination percentages and the person responsible for accepting findings.

Expected Reporting Deliverables

A weld register or map links method, extent, result and any re-test to each examined joint. Reports identify the acceptance basis, inaccessible areas and items awaiting engineering disposition.

Applications

Weld Inspection is applied across a wide range of assets and industries, including:

  • Structural fabrications, pressure components, pipe spools and repair welds need traceable weld identifiers, material details and the relevant design or fabrication specification.
  • Inspection planning for construction assets and operators
  • Inspection planning for manufacturing assets and operators
  • Inspection planning for mining assets and operators

Standards & Competence Context

The references below are planning context, not a claim of accreditation, certified compliance or a universal acceptance rule. Confirm the applicable edition, part, material, procedure and acceptance criteria for this asset. Verify the appointed personnel's method, level and sector competence, insurance and any engineering authority required for the scope before work. A method standard is not itself a return-to-service approval.

  • AS/NZS 1554 — Structural steel welding
  • AS 2207 — Ultrasonic testing of welds
  • AS 1171 — Magnetic particle testing

Why Choose NDT Australia

  • One enquiry point for scope and specialist-partner co-ordination
  • Asset-linked findings with examination extent and limitations
  • Separate identification of engineering and operational decisions

Frequently Asked Questions

No. Examination of production welds is separate from welder and procedure qualification. Any qualification testing or sign-off needs its own verified scope and responsible parties.

Agree hold points before coating, assembly or loading conceals examination faces. Supply weld preparation details, specified examination percentages and the person responsible for accepting findings.

A weld register or map links method, extent, result and any re-test to each examined joint. Reports identify the acceptance basis, inaccessible areas and items awaiting engineering disposition.

Related Services

Explore complementary inspection scopes. Method, specialist partner and availability are confirmed for the asset and location.